A very wide range of ultraviolet lamps from low power hand held models to high intensity units is available. There are filtered lamps in three wavelengths for use in fluorescent techniques and unfiltered lamps in both long and short (germicidal) wavelengths. All incorporate an extruded, anodised aluminium housing and a specially designed unique profile has been developed for the hand held lamps. The operator friendly shape permits lamps to be held easily with gloved hands.

Filtered lamps
These highly efficient, well designed lamps are produced in three wavelengths: 254, 312 and 365nm and dual wavelength combinations. Power ranges from a single 4W tube up to two 15W tubes.
Applications include:
Short wavelength (254nm): Fluorescence techniques, fluorochemistry, mineralogy, photopolymerisation, mutation studies, toxicology.
Mid wavelength (312nm): Electrophoresis gel viewing.
Long wavelength (365nm): TLC plate viewing, fluorochemistry, food inspection, quality control, titration, pesticide analysis, mineralogy

Ordering UVIlite filtered UV lamps

LF 104S 50 x 75 1 x 4W 254 340
LF 204LS50 x 75 1 x 4W 365 350
1 x 4W 254 265
LF 106L 50 x 150 1 x 6W 365 700
LF 106S 50 x 150 1 x 6W 254 710
LF 106M 50 x 150 1 x 6W 312 680
LF 206LM 50 x 150 1 x 6W 312 580
1 x 6W 365 610
LF 206MS 50 x 150 1 x 6W 312 580
1 x 6W 254 400
LF 206LS 50 x 150 1 x 6W365 610
1 x 6W 254 400
LF 215L 80 x 300 2 x 15W 365 2300
LF 215S 80 x 300 2 x 15W 254 1780
LF 215M 80 x 300 2 x 15W 312 2200
LF 215LM 80 x 300 1 x 15W 365 1350
1 x 15W 312 1330
LF 215MS 80 x 300 1 x 15W 312 1330
1 x 15W 254 930
LF 215LS 80 x 300 1 x 15W 365 1350
1 x 15W254 930

Intensity at 15cm µW/cm2

Unfiltered ultraviolet lamps

Germicidal lamps

Widely used in medical and scientific research laboratories as well as in electronics and the food and beverage industries. Areas that must be kept free from bacterial contamination may be irradiated with UVItec germicidal lamps, provided safeguards are in place to protect operators. The same range of lamps is available with either BL or BLB long-wavelength tubes:

  • Unfiltered UV longwaves (BL blacklight / BLB blacklight blue)
    BL (Blacklight) tubes are actinic ultraviolet type and include a white light component in the output. Applications: Polymer curing, adhesive curing, dermatology, pharmacology, photoresist exposure.
    BLB (Blacklight Blue) tubes are self-filtered cobalt glass – to reduce the visible light component and increase fluorescent contrast. Non-destructive testing, quality control, invisible coding/marking, counterfeit note detection, rodent contamination detection, readmission control, aflatoxin detection, signature verification.

  • UVIlite Unfiltered UV germicidal lamps 254nm
    Model Number Tubes Intensity µW/cm2
    LI 206G 2 x 6W 1400 *
    LI 208G 2 x 8W 1800 *
    LI 215G 2 x 15W76
    LI 315G 3 x 15W95
    LI 220G 2 x 20W95
    LI 320G 3 x 20W119
    LI 230G 2 x 30W152
    LI 330G 3 x 30W191
    LI 240G 2 x 40W157
    LI 340G 3 x 40W219
    Intensities all at 1m except* at 15cm
    UVIlite Unfiltered UV longwave lamps 365nm
    Model Number Tubes Intensity µW/cm2
    LI 206BL 2 x 6W BL1215 *
    LI 208BL 2 x 8W BL1400 *
    LI 215BL 2 x 15W BL108
    LI 315BL 3 x 15W BL147
    LI 220BL 2 x 20W BL129
    LI 320BL 3 x 20W BL177
    LI 230BL 2 x 30W BL228
    LI 330BL 3 x 30W BL312
    LI 240BL 2 x 40W BL302
    LI 340BL 3 x 40W BL413
    LI 206BLB2 x 6W BLB1120 *
    LI 208BLB2 x 8W BLB1300 *
    LI 215BLB2 x 15W BLB100
    LI 315BLB3 x 15W BLB136
    LI 220BLB2 x 20W BLB119
    LI 320BLB3 x 20W BLB163
    LI 230BLB2 x 30W BLB210
    LI 330BLB3 x 30W BLB288
    LI 240BLB2 x 40W BLB279
    LI 340BLB3 x 40W BLB381

    Intensities all at 1m except* at 15cm

    Germicidal radiation required for bacterial destruction

    Bacteria Energy in mW-sec/cm2
    Sterilisation up to 90%
    Energy in mW-sec/cm2
    Sterilisation up to 99%
    Bacillus anthracis 4.52 9.04
    S. enteritidis 4.00 8.00
    B. megatherium sp.(veg.) 1.30 2.60
    B. megatherium sp.(spores) 2.73 5.46
    B.paratyphosus 3.20 6.40
    B.subtilis 7.10 14.20
    B. subtilis spores 12.00 24.00
    Corynebacterium diphtheriae 3.37 6.74
    Eberthella typhosa 2.14 4.28
    Escherichia coli 3.00 6.00
    Micrococcus candidus 6.05 12.10
    Micrococcus sphaeroides 10.00 20.00
    Neisseria catarrhalis 4.40 8.80
    Phytomonas tumefaciens. 4.40 8.80
    Proteus vulgaris 2.64 5.28
    Pseudomonas aeruginosa 5.50 11.00
    Pseudomonas fluorescens 3.50 7.00
    S. typhimurium 8.00 16.00
    Sarcina Lutea 19.70 39.40
    Seratia marcescens 2.42 4.84
    Dysentery bacilli 2.20 4.40
    Shigella paradysenteriae 1.68 3.36
    Spirillum rubrum 4.40 8.80
    Staphylococcus albus1.84 3.68
    Staphylococcus aureus 2.60 5.20
    Streptococcus hemolyticus 2.16 4.32
    Streptococcus lactis 6.15 12.30
    Streptocuccus viridans 2.00 4.00


    DISCLAIMER: THE ABOVE TABLE IS ONLY A GUIDELINE FROM UVItec FOR THE DESTRUCTION OF BACTERIA.
    UVItec / Laboratorium CANNOT BE HELD RESPONSIBLE FOR ANY ERRORS FOUND IN THE TABLE.